CONSTRUCTION
 
The standard construction is horizontal foot mounted design, single or multistage radially split casing clamped together by external tie-bolts and sealed with gaskets.
 
SUCTION AND DELI EVERY NOZZLES:
 
The standard design is Vertical Delivery and suction nozzles in oval flange for low head and low capacities designated as SHP OF series and round flanges for high head and higher capacities designated as SHP RF Series.
 
DRIVE
 
The prime mover is directly connected to the pump through a flexible coupling.
 
DIRECTION OF ROTATION
 
The direction of rotation is clockwise as viewed from the coupling end
 
SEALING ARRANGEMENTS

 
SHP OF series pumps is fitted with standard mechanical seal for leak proof operation.
 
SHP RF series pumps are fitted with conventional soft graphite lubricated glands in the stuffing box mechanical seals can be provided in this model on specific request.

 
DESIGN
 
These pumps are regenerative types. These are suitable for lifting liquids from a depth of 8 meters. These are available with hot water construction for operating temperatures of up to 100 degrees C.
 
MATERIAL OF CONSTRUCTION
 
Suction/Delivery Casings C.I. Gr.20
Impellers Bronze
Shaft AISI 410
Bearings Standard Deep Groove Ball Bearings
And Bush Bearings
Keys AISI 410
Clamping Studs EN-8